Meeting Name: Development Review Committee Agenda status: Final
Meeting date/time: 3/11/2024 9:00 AM Action Summary status: Draft  
Meeting location: Office of the County Engineer
Published agenda: Agenda Agenda Published Action Summary: Not available Meeting Extra1: Not available  
Agenda packet: Agenda Packet Agenda Packet
Meeting video:  
Attachments:
File #Ver.Agenda #TypeTitleActionResultVideo
     MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING.   Not available
   1. ROLL CALL   Not available
   2. PLEDGE OF ALLEGIANCE   Not available
   3. ADOPT THE FOLLOWING MINUTES:   Not available
2024-14463 13.1.MinutesMarch 4, 2024   Not available
   4. PUBLIC COMMENT   Not available
   5. CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL   Not available
2024-14464 15.1.ConsentLiquor Lane - Major Site Plan Project #2023070013 #30369 EDA Consultants   Not available
2024-14466 15.2.Consent7058 SW 129TH Place - Waiver Request to Water Main Extension Project #2024020095 #31219 Parcel #8010-0903-06 Permit #2024020340 Brite Properties of Florida LDC 6.14.2.A(3) - Water Main Extension to Farthest Property Corner CODE states When property is within connection distance, the water main shall be extended to the farthest property line. Refer to Sec. 6.15.3.B for fire hydrant installation requirements. APPLICANT states Water main exists at parcel's lot line but not across as is required by Code. CONDITIONAL WAIVER approved provided applicant (1) opens a water utility account with MCU; (2) pays all Connection charges; and (3) pays $5K capital connection fee as this is part of a pending ARPA grant to design and extend water main for all gaps in Marion Oaks Unit 7/10.   Not available
2024-14467 15.3.ConsentMcDowell Dodd P & McDowell Jill M - Waiver Request for Family Division 3150 SE HWY 42 Summerfield Project #2024020100 #31229 Parcel #44773-000-00 McDowell Dodd P LDC 2.16.1.B(10) - Division of Land CODE states Family Division. A parcel of record as of January 1, 1992 that is located in the Rural Land may be subdivided for use of immediate family members for their primary residences. Within the Farmland Preservation area, each new tract and the remaining parent tract must be at least three (3) acres in size. Within the Rural Land outside of the Farmland Preservation area each new tract and the remaining parent tract must be at least one acre in size. In the Urban Area, only parcels of record as of January 1, 1992 which are low density residential property exceeding two acres in size may be divided for the use of immediate family members for their primary residences up to the maximum density of one dwelling unit per gross acre. Immediate family is defined as grandparent, parent, step-parent, adopted parent, sibling, child, step-child, adopted child, or grandchild. A   Not available
   6. SCHEDULED ITEMS:   Not available
2024-14468 16.1.New BusinessOcala 3 Parking - Waiver Request to Major Site Plan in Review Project #2023050052 #31084 Parcel #23191-002-00 Menadier Engineering LDC 6.7.4. - Shade trees CODE states Shade trees are required for all developments excluding residential developments. A. The post-development ratio of shade trees to the area of the site shall be a minimum of one shade tree per 3,000 square feet. B. Shade trees may include: (1) Protected and preserved trees which have a favorable assessment, and/or (2) Trees as required for buffers, parking areas, vehicle use areas, and building areas, and/or (3) Trees as required as replacement trees. C. When mature trees with a full canopy of 30-foot radius or larger, with a favorable assessment, are preserved on the project site, a credit of two shade trees may be used towards the overall shade tree requirement. D. Required shade trees shall meet the minimum size requirements in Section 6.8.10.C. APPLICANT requests waiver to minimum number of shade tree requirements. The proposed project is a truck parking lot. We are providing an enhanced buffer a   Not available
2024-14470 16.2.New BusinessRD Plaza Warehouses - Waiver Request to Major Site Plan in Review Project #2024010064 #31078 Parcel #9024-0565-09 Menadier Engineering LDC 6.11.5.C(1) - Driveway access CODE The minimum allowed distance between a commercial driveway and the nearest intersecting roadway or driveway shall be as shown in Table 6.11-2. APPLICANT states Driveway proposed 176-ft from PC to PC; 213-ft from PC to CL of proposed driveway; and if measured from edge of pavement to edge of pavement, the distance is 241-ft. We located the driveway as far from the intersection as possible. County requires 245-ft for roads with 35 mph or less. This portion of roadway is 30 mph. We're requesting a waiver to driveway spacing for the driveway on Chestnut Road. LDC 6.8.6.K(2) - Buffers CODE states B-Type buffer shall consist of a 20-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of t   Not available
2024-14471 16.3.New BusinessMidway Terrace Apartments - Waiver Request to Major Site Plan in Review Project #2023050037 #30147 Parcel #9007-0101-17 Linn Engineering & Design LDC 6.13.6.A(3)(c) - Stormwater quality criteria CODE states Dry retention systems that have a depth of six feet or less, measured from top of bank to pond bottom, with side slopes that are no steeper than 4:1 and sodded bottoms. APPLICANT states DRAs is 5' deep and is required to be sodded on sides and bottom. Alternatively, seed and mulch may be pursued via waiver. Applicant must adhere to FDOT Specification section 570 for establishment requirements. Proposed DRA stabilization method is included on the DRA cross section. LDC 2.12.8. - Current boundary and topographic survey CODE states Current boundary and topographic survey (one-foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre   Not available
2024-14472 16.4.New BusinessMidway Terrace Apartments 9007-0101-18 - Waiver Request to Major Site Plan in Review Project #2023050074 #30183 Parcel #9007-0101-18 Linn Engineering & Design LDC 6.13.6.A(3)(c) - Stormwater quality criteria CODE states Dry retention systems that have a depth of six feet or less, measured from top of bank to pond bottom, with side slopes that are no steeper than 4:1 and sodded bottoms. APPLICANT states DRAs is 5' deep and is required to be sodded on sides and bottom. Alternatively, seed and mulch may be pursued via waiver. Applicant must adhere to FDOT Specification section 570 for establishment requirements. Proposed DRA stabilization method is included on the DRA cross section. LDC 2.12.8 - Current boundary and topographic survey CODE states Current boundary and topographic survey (one-foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be   Not available
2024-14474 16.5.New BusinessWEC - Arena 6 Modification - Standalone Waiver Request to Previously Approved Major Site Plan Revision Project #2023060027 #31227 Parcel # 21068-002-00, 21056-000-00 & 12674-001-00 Tillman & Associates Engineering LDC 6.7.4. - Shade trees CODE states Shade trees are required for all developments excluding residential developments. A. The post-development ratio of shade trees to the area of the site shall be a minimum of one shade tree per 3,000 square feet. B. Shade trees may include: (1) Protected and preserved trees which have a favorable assessment, and/or (2) Trees as required for buffers, parking areas, vehicle use areas, and building areas, and/or (3) Trees as required as replacement trees. C. When mature trees with a full canopy of 30-foot radius or larger, with a favorable assessment, are preserved on the project site, a credit of two shade trees may be used towards the overall shade tree requirement. D. Required shade trees shall meet the minimum size requirements in Section 6.8.10.C. APPLICANT requests waiver for tree requirements to be waived or modified t   Not available
2024-14475 16.6.New BusinessCalesa Township - Self-Storage Facility - Waiver Request to Major Site Plan in Review 6140 SW 38th St Ocala Project #2023040107 #30062 Parcel #35300-000-14 Tillman $ Associates Engineering LDC 2.12.8. - Current boundary and topographic survey CODE states Current boundary and topographic survey (one-foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor. APPLICANT requesting a waiver to provide a survey that does not provide one-foot contours extending 100 feet beyond the project boundary. The survey does not extend outside the property line to the south. Existing LiDAR will be used for the area. Staff supports the waiver. LDC 6.11.4.B.(1 & 2) - Access management CODE states Cross Access (Parallel Access). (1) Cross access is required to reduce the use of the public street system, provi   Not available
2024-14476 16.7.New BusinessCarson L / Carson Brothers Property - Standalone Waiver Request 181 SW 80TH AVE OCALA Project #2021080049 #31222 Parcel #23209-000-00 Tillman & Associates Engineering LDC 6.11.5.C.1 Driveway Spacing CODE states the minimum allowed distance between a commercial driveway and the nearest intersecting roadway or driveway shall be as shown in Table 6.11-2. APPLICANT requests a waiver as the code calls for 440' spacing. This is a request to reduce separation of existing driveway spacing for site plan to be submitted in the future. This is in conjunction with SW 80th Avenue project.   Not available
2024-14477 16.8.New BusinessVelazco Barn Replacement - Waiver Request to Major Site Plan 6133 SE 123RD LN Belleview Project #2024020089 #31207 Parcel #45369-002-00 Jennifer’s Permitting Service LDC 2.21.1.A(1) - Major Site Plan CODE states a Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests a waiver to a Major Site Plan to address stormwater control; owner is replacing an existing barn with a new one (3172 square feet) total impervious square feet to become approx. 15.81% on his 2.46-acre parcel. Owner is working with a surveyor to create a survey/site plan to show all structures. SF and can show a DRA to meet storm water requirements.   Not available
2024-14478 16.9.New BusinessQuail Meadow Property Owners Association, Inc. - Road Closing / Abrogation Project #2023090091 #30691 Quail Meadow Property Owners Association, Inc. Tabled from 10/16/23 and 1/22/24 to allow more time to work with staff regarding gates and current maintenance. Applicant provided revised proposed gate drawings. The Petitioner is requesting to privatize all the dedicated road(s), rights-of-way and appurtenant drainage facilities within the Plat of Quail Meadow, Plat Book Y, Pages 89-91.   Not available
   7. CONCEPTUAL REVIEW ITEMS:   Not available
   8. DISCUSSION ITEMS:   Not available
   9. OTHER ITEMS:   Not available
   10. ADJOURN:   Not available